Datastream : AOSCCN200

AOS: Dual Column Cloud Condensation Nuclei Counter

Active Dates
2012.06.24 - 2013.03.10

Measurement Categories
Aerosols, Cloud Properties

Originating Instrument
Aerosol Observing System (AOS)

Measurements

Only measurements considered scientifically relevant are shown below by default.

Show all measurements

Measurement Units Variable
AOS CCN set point temperature for the optical partical counter (OPC), first CCN degrees C CCN_OPC_set_1 ( time )
AOS CCN set point temperature for the optical partical counter (OPC), second CCN degrees C CCN_OPC_set_2 ( time )
AOS CCN sample pressure, first CCN hPa CCN_P_sample_1 ( time )
AOS CCN sample pressure, second CCN hPa CCN_P_sample_2 ( time )
AOS CCN volumetric flowrate of sample air, first CCN cm^3/minute CCN_Q_sample_1 ( time )
AOS CCN volumetric flowrate of sample air, second CCN cm^3/minute CCN_Q_sample_2 ( time )
AOS CCN volumetric flowrate of sheath air, first CCN cm^3/minute CCN_Q_sheath_1 ( time )
AOS CCN volumetric flowrate of sheath air, second CCN cm^3/minute CCN_Q_sheath_2 ( time )
AOS CCN temperature of the optical particle counter, first CCN degrees C CCN_T_OPC_1 ( time )
AOS CCN temperature of the optical particle counter, second CCN degrees C CCN_T_OPC_2 ( time )
AOS CCN temperature of sample air at entrance to instrument, first CCN degrees C CCN_T_inlet_1 ( time )
AOS CCN temperature of sample air at entrance to instrument, second CCN degrees C CCN_T_inlet_2 ( time )
AOS CCN Nafion temperature, first CCN degrees C CCN_T_nafion_1 ( time )
AOS CCN Nafion temperature, second CCN degrees C CCN_T_nafion_2 ( time )
AOS CCN observed temperature at top of column, first CCN degrees C CCN_T_read_TEC1_1 ( time )
AOS CCN observed temperature at top of column, second CCN degrees C CCN_T_read_TEC1_2 ( time )
AOS CCN observed temperature at middle of column, first CCN degrees C CCN_T_read_TEC2_1 ( time )
AOS CCN observed temperature at middle of column, second CCN degrees C CCN_T_read_TEC2_2 ( time )
AOS CCN (read) temperature at bottom of column, first CCN degrees C CCN_T_read_TEC3_1 ( time )
AOS CCN (read) temperature at bottom of column, second CCN degrees C CCN_T_read_TEC3_2 ( time )
AOS CCN temperature of sample air entering the column, first CCN degrees C CCN_T_sample_1 ( time )
AOS CCN temperature of sample air entering the column, second CCN degrees C CCN_T_sample_2 ( time )
AOS CCN set point for temperature at top of column, first CCN degrees C CCN_T_set_TEC1_1 ( time )
AOS CCN set point for temperature at top of column, second CCN degrees C CCN_T_set_TEC1_2 ( time )
AOS CCN set point for temperature at middle of column, first CCN degrees C CCN_T_set_TEC2_1 ( time )
AOS CCN set point for temperature at middle of column, second CCN degrees C CCN_T_set_TEC2_2 ( time )
AOS CCN set point for temperature at bottom of column, first CCN degrees C CCN_T_set_TEC3_1 ( time )
AOS CCN set point for temperature at bottom of column, second CCN degrees C CCN_T_set_TEC3_2 ( time )
CCN alarm code expressed as a summation of powers of 2. 0 indicates no detected problem unitless CCN_alarm_code ( time )
AOS CCN voltage used by DMT for OPC diagnostic purposes, first CCN volt CCN_baseline_monitor_1 ( time )
AOS CCN voltage used by DMT for OPC diagnostic purposes, second CCN volt CCN_baseline_monitor_2 ( time )
First stage monitor voltage, first CCN V) CCN_first_stage_monitor_voltage_1 ( time )
Second stage monitor voltage, second CCN V) CCN_first_stage_monitor_voltage_2 ( time )
AOS CCN set point temperature for the inlet manifold, first CCN degrees C CCN_inlet_set_1 ( time )
AOS CCN set point temperature for the inlet manifold, second CCN degrees C CCN_inlet_set_2 ( time )
AOS CCN OPC laser current, first CCN mA CCN_laser_current_1 ( time )
AOS CCN OPC laser current, second CCN mA CCN_laser_current_2 ( time )
AOS CCN set temperature for the Nafion humidifier, first CCN degrees C CCN_nafion_set_1 ( time )
AOS CCN set temperature for the Nafion humidifier, second CCN degrees C CCN_nafion_set_2 ( time )
Number of particles that are larger than 10um, first CCN count CCN_overflow_1 ( time )
Number of particles that are larger than 10um, second CCN count CCN_overflow_2 ( time )
CCN Proportional valve voltage, first CCN V CCN_proportional_valve_voltage_1 ( time )
CCN Proportional valve voltage, second CCN V CCN_proportional_valve_voltage_2 ( time )
AOS CCN sample saturation setpoint value reported by instrument, first CCN % CCN_ss_set_1 ( time )
AOS CCN sample saturation setpoint value reported by instrument, second CCN % CCN_ss_set_2 ( time )
Hexadecimal flag, non-zero value means instrument is not operating stably, first CCN unitless CCN_temp_unstable_flag_1 ( time )
Hexadecimal flag, non-zero value means instrument is not operating stably, second CCN unitless CCN_temp_unstable_flag_2 ( time )
CCN temperature gradient, first CCN degrees C CCN_temperature_gradient_1 ( time )
CCN temperature gradient, second CCN degrees C CCN_temperature_gradient_2 ( time )
Size of upper limit of each CCN bin um CCN_upper_size_limit ( num_bins )
AOS number concentration of CCN, first CCN 1/cm^3 N_CCN_1 ( time )
AOS number concentration of CCN, second CCN 1/cm^3 N_CCN_2 ( time )
AOS bin number of lowest channel of OPC include in summation of N_CCN, first CCN unitless N_CCN_bin_number_1 ( time )
AOS bin number of lowest channel of OPC include in summation of N_CCN, second CCN unitless N_CCN_bin_number_2 ( time )
AOS CCN number concentration by bin, first CCN count N_CCN_dN_1 ( time, num_bins )
AOS CCN number concentration by bin, second CCN count N_CCN_dN_2 ( time, num_bins )
Altitude above mean sea level m alt
Base time in Epoch seconds since 1970-1-1 0:00:00 0:00 base_time
North latitude degree_N lat
East longitude degree_E lon
Time offset from midnight time ( time )
Time offset from base_time time_offset ( time )

Locations

  • ARM Mobile Facility (PVC)
    • Highland Center, Cape Cod MA; MAOS (S1)
    • Highland Center, Cape Cod MA; MAOS (S1)